Tech Specs

Tech Specs

Output Current

12.5A

Output Voltage

24V

Output Voltage Range

Output Voltage Adjustment Range

V1: 22-28Vdc

Output Power

300W

Output Current Adjustment Range

Max Output Voltage

Buffering Time

-

Line Regulation

< 0.5% typ. (@ 85-264Vac input, 100% load)

Load Regulation

< 1% typ. (@ 85-264Vac input, 0-100% load)

PARD

V1: <100mVpp , V2 SB: <200mVpp

Start-up Time

< 1000ms @ nominal input (100% load)

Hold-up Time

> 15ms @ Nominal input, 100% load

Dynamic Response (Overshoot & Undershoot O/P Voltage)

± 5% @ 85-264Vac input, 0-100% load (Slew Rate: 0.1A/μS, 50% duty cycle @ 5Hz)

Start-up with Capacitive Loads

8,000µF Max

Remote ON/OFF

-

Protective Device

-

Voltage Drop Between Input and Output

-

Residual Ripple/PARD (20MHz)

-

Residual Ripple

-

Max. Power

-

Ripple & Noise

-

LED System Voltage Range in CC Mode

-

Rise Time

-

Power Boost Duration

-

Power Boost Recovery Time

-

Nominal Input Voltage

100-240Vac

Input Voltage Range

85-264Vac

Max Input Voltage

-

Nominal Input Frequency

50-60Hz

Input Frequency Range

47-63Hz

Nominal DC Input Voltage

125-250Vdc

DC Input Voltage Range

125-375Vdc

Input Current

< 4.0A @ 115Vac,
< 2.0A @ 230Vac

Input Power (Standby Mode)

-

Efficiency at 100% load

> 86% @ 115Vac,
> 88% @ 230Vac

Inrush Current

< 35A @ 115Vac,
< 70A @ 230Vac

Charging Time

-

Power Factor at 100% load

> 0.99 @ 115Vac,
> 0.97 @ 230Vac

Leakage Current

< 1mA @ 240Vac

Nominal Current

-

Total Harmonic Distortion

-

Power Dissipation

0% load: < 4.4W @ 115Vac & < 4.0W @ 230Vac
100% load: < 49W @ 115Vac & < 38W @ 230Vac

Efficiency @ 10% load

-

Case Chassis / Cover

Aluminium

Indicator

-

Cooling System

Built-in Fan

Input Terminal

-

Output Terminal

-

Signal Terminal

-

Noise Sound Pressure Level (SPL)

-

Input/Output Terminal

-

Signal

-

Mounting Rail

-

Wire

-

Protection Structure

-

Terminal

-

Unit Weight

0.82 kg (1.81 lb)

Dimensions

199 x 105 x 41 mm
7.83” x 4.13” x 1.61”

Vibration (Operating)

-

Shock Test (Operating)

-

Operating Temperature

-10°C to +70°C

Storage Temperature

-25°C to +85°C

Power De-rating

> 50°C de-rate power by 2.5% /°C

Operating Humidity

< 95% RH

Shock Test (Non-Operating)

IEC60068-2-27, 30G (300m/S²) for a duration of 18ms 3 times per direction, 18 times in total

Vibration (Non-Operating)

IEC60068-2-6, 10Hz to 150Hz @ 50m/S² (5G peak); 20 min per axis for all X, Y, Z direction

Storage Humidity

-

Operating Altitude

-

Pollution Degree

-

Bump Test (Operating)

-

Over Voltage Category

-

Corrosion

-

Overvoltage

V1: < 32V ±10%, V2 SB: < 16V ±15%, SELV output, Hicc-up Mode, Non-Latching (Auto recovery).

Overload / Overcurrent

> 120% of rated load current, Hicc-up Mode, Non-Latching (Auto recovery).

Over Temperature

< 75°C Ambient Temp@ 100% load, Non-Latching (Auto-recovery).

Short Circuit

Hicc-up Mode, Non-Latching (Auto-recovery when the fault is removed).

Reverse Polarity Protection

-

Degree of Protection

IP20

Protection Against Shock

Class I with Primary Earth connection

Input Polarity Protection

-

Battery Polarity Protection

-

Wrong Battery Voltage Protection

-

Deep Discharge Protection

-

Overload

-

Overcurrent

-

Internal Fuse

-

Insufficient Input Voltage Protection

-

MTBF

> 700,000 hrs per Telcordia SR-332

Expected Cap Life Time

-

Safety Certificate

-

Electrical Safety

SIQ Bauart: EN 60950-1, EN 62368-1
UL/cUL recognized: UL60950-1 and CSA C22.2 No. 60950-1
UL 62368-1 and CSA C22.2 No. 62368-1
CB scheme : IEC 60950-1, IEC 62368-1
CCC: GB4943

CE

In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU

Medical Safety

-

Galvanic Isolation

Input to Output: 3.0 KVac
Input to Ground: 1.5 KVac
Output to Ground: 500 Vac

Industrial Control Equipment

-

Hazardous Location / ATEX

-

II 3 G ATEX 2014/34/EU

-

Electrical Equipments of Machines

-

Electrical Equipment for Use in Electrical Power Installations

-

Safety Entry Low Voltage

-

Maritime

-

Material and Parts

-

Isolation Resistance

-

PE Resistance

-

UKCA

In conformance with Electrical Equipment (Safety) Regulations 2016 No. 1011 and
The Electromagnetic Compatibility Regulations 2016 No. 1091

Certificates for Other Countries

-

BIS

-

KC

K 60950-1

Electrical Equipment for Measurement, Control, and Laboratory Use

-

ITE Safety

-

SIL3

-

Emission

Generic Standards: CISPR 32, EN/BS EN 55032, KN 32 FCC Title 47: Class B, GB 9254

Immunity

Generic Standards: EN/BS EN 55024, KN 35

Harmonic Current Emissions

IEC/EN/BS EN 61000-3-2, Class A

Voltage Fluctuation and Flicker

IEC/EN/BS EN 61000-3-3

ESD Immunity

-

Radiated Immunity

-

EFT

-

Surge

-

Conducted Immunity

-

Magnetic Field

-

Voltage Dips

-

Component Power Supply for General Use

-

Nominal Battery Voltage

-

Battery Voltage Range

-

Battery Capacity

-

Battery Charging Mode

-

End of Charge Voltage

-

Battery Fuse

-

Battery Discharging Voltage Range

-

Battery Charging Current

-

Battery Current Consumption

-

Discharging Current

-

Recommended Charging Voltage

-

Delta PMC-24V300W1BA 24V 300W 12.5A Panel Mount PMC Series (2024)
Top Articles
Latest Posts
Article information

Author: Pres. Carey Rath

Last Updated:

Views: 5507

Rating: 4 / 5 (61 voted)

Reviews: 92% of readers found this page helpful

Author information

Name: Pres. Carey Rath

Birthday: 1997-03-06

Address: 14955 Ledner Trail, East Rodrickfort, NE 85127-8369

Phone: +18682428114917

Job: National Technology Representative

Hobby: Sand art, Drama, Web surfing, Cycling, Brazilian jiu-jitsu, Leather crafting, Creative writing

Introduction: My name is Pres. Carey Rath, I am a faithful, funny, vast, joyous, lively, brave, glamorous person who loves writing and wants to share my knowledge and understanding with you.